Peak-to-Peak Voltage Calculator – Convert AC Voltage Measurements
Convert between peak, RMS, average, and peak-to-peak voltage for sine waves.
Select your input type
Choose whether you have peak voltage, RMS voltage, or average voltage.
Enter the voltage value
Input your known voltage value. The calculator will convert to all other measurements.
Click Convert
Get peak-to-peak, peak, RMS, and average voltage values for a sine wave.
| From | To Peak-to-Peak | To Peak | To RMS |
|---|---|---|---|
| Peak (Vp) | Vpp = 2 × Vp | Vp = Vp | Vrms = Vp / √2 |
| Peak-to-Peak (Vpp) | Vpp = Vpp | Vp = Vpp / 2 | Vrms = Vpp / (2√2) |
| RMS (Vrms) | Vpp = 2√2 × Vrms | Vp = √2 × Vrms | Vrms = Vrms |
| Average (Vavg) | Vpp = π × Vavg | Vp = π/2 × Vavg | Vrms = π/(2√2) × Vavg |
Peak Voltage (Vp)
Peak voltage is the maximum voltage measured from zero to the highest point of the sine wave. It represents the amplitude of the AC signal. For a 120V RMS household outlet, the peak voltage is about 170V.
Peak-to-Peak Voltage (Vpp)
Peak-to-peak voltage measures from the negative peak to the positive peak — the full vertical span of the waveform. It equals twice the peak voltage. Oscilloscopes typically display peak-to-peak values.
RMS Voltage (Vrms)
RMS (Root Mean Square) voltage is the DC equivalent that would deliver the same power to a resistive load. When we say "120V AC," we mean 120V RMS. For sine waves, Vrms = Vp / √2 ≈ 0.707 × Vp.
Average Voltage (Vavg)
Average voltage is the mean value over one half-cycle of a rectified sine wave. For a full sine wave, the average is zero (equal positive and negative halves). Vavg = 2/π × Vp ≈ 0.637 × Vp.
US Household Power (120V RMS)
Vp = 170V, Vpp = 340V, Vavg = 108V. The actual voltage swings from -170V to +170V, 60 times per second.
European Household Power (230V RMS)
Vp = 325V, Vpp = 650V, Vavg = 207V. Higher voltage means more power delivery with less current.
Audio Line Level (1V RMS typical)
Vp = 1.41V, Vpp = 2.83V. Professional audio uses +4dBu (1.23V RMS), consumer uses -10dBV (0.316V RMS).
Transformer Secondary (12V RMS)
Vp = 17V, Vpp = 34V. After rectification and filtering, you get about 17V DC minus diode drops.
Frequently Asked Questions
Other Free Tools
Rms Value Calculator
RMS Value Calculator – Calculate Root Mean Square Voltage
Voltage Calculator
Voltage Calculator
Ohms Law Calculator
Ohm's Law Calculator
Electric Power Calculator
Electric Power Calculator
Ac Impedance Calculator
AC Impedance Calculator – Calculate Impedance in AC Circuits
Current Calculator
Current Calculator – Calculate Electrical Current (Amps)